CALL US

02 9543 7377

100,200 and 300 Series BET Surface Area and Pore Size Analyzer

Single-/Multipoint BET Surface Area BJH Adsorption and Desorption Horvath-Kawazoe Saito-Foley Material Research Chemical Engineering New Energy Catalytic Technologies Range of Pore Diameter 0.35–500nm Range of Specific Surface Area >0.0001m2/g Repeatability of Median Pore Diameter <0.02 Repeatability of Specific Surface Area ±1% Choose between 1,2 or 3 analysis ports

Product Category: Gas Adsorption, Pore Size Determination and Distribution, Surface Area

Industry: Membrane Manufacture and Testing, Particle and surface science

Supplier: JWGB

Description

The JWGB 100 Series can accurately produce surface area and pore size results of powder materials. According to the different test functions, this series of instruments are divided into three types, there are A, B, and C, the C type is configured with 1 torr or 0.1 torr high-sensitive pressure sensors and turbo molecular pump with ultimate pressure of 10-8 Pa, it can effectively take microporous analysis of microporous materials such as molecular sieve, catalyst, activated carbon, and other microporous materials.

 

Datasheet

Datasheet

Features

Test Module

Internal temperature of test module can be controlled through Real-time monitoring, ensuring accuracy of adsorption detection.

Saturated Vapor Pressure P0

Using independent P0 pressure sensor for P0 value by inching test, guarantees the reliability of experimental data. Atmospheric pressure input method to determine P0 also be selected.

Datasheet

Vacuum System

It’s a multi-channel, adjustable, and parallel vacuum system. Vacuum degree of this system can be controlled in segments. This design prevents the sample from being pumped into analyzer. Meanwhile, a delicate part was designed for ensuring cleanliness of vacuum system, minimizing dust pollution.

Sample Preparation System

In addition to two pretreatment stations, the other two analysis stations can be used in preparing samples. There is no interference between pretreatment stations and analysis stations. Degas temperature can be set individually and controlled from ambient to 400 ℃.

Micropore Distribution

Accurately apply the HK method, SF method and other micropore analysis model, the aperture deviation of micropore is less than 0.02 nm.

Pressure Sensor

Micro 100C with 1torr (selectable 0.1torr) makes the partial pressure of P/P0 up to 10-7 - 10-8 (N2/77K) in the physical adsorption analysis.

Datasheet

Cold Free Space

Cold free space can be corrected by Helium automatically, ensuring accuracy of test results.
This calibration method is suitable for testing of any powder or particle material.

Control of Liquid Nitrogen level

Using High volume (3L) Dewar flasks and working with the seal cover assure a constant thermal profile along the length of sample tubes and P0 tubes throughout testing process.

Turbo Molecular Pump

Molecular pump is a standard configuration part on the Micro 100C. The ultimate pressure is up to 10-8 Pa, providing a strong support for micropore analysis in the ultra-low pressure. The smallest micro-pore diameter can be tested is 0.35 nm.

JWGB-BK Control and Analysis Software

JWGB-BK Software is intelligent software in operation control, data acquisition, calculation and analysis and report generation on the Windows platform. This software can communicate with the host through the LAN port and remotely control many instruments at the same time.

 

Clear tabular reports include:
Adsorption and desorption isotherms
Single-/Multipoint BET surface area
Langmuir surface area
STSA-surface area
pore size distribution according to BJH
t-plot
Dubinin-Radushkevich
Horvath-Kawazoe
Saito-Foley

 

Datasheet

 

Datasheet

JWGB-BK Software adopts a unique intake control method, the pressure in adsorption and desorption process is optimally set in six- stage; this flexible design is helpful for improving test efficiency.

 

Datasheet

 

Changes of the pressure and temperature inside the manifold can be observed directly in the test interface which is convenient for sample test and instrument maintenance.
Current state of analyzer can be intuitively understood with the indicator light and event bar.
Each adsorption equilibrium process is dynamically displayed on the test interface. Adsorption characteristics of the sample can be easily understood.

 

Datasheet

Typical analysis examples

BET repeatability is only 0.0015 m2 / g in the test of very low surface area powder

DatasheetDatasheet

Analysis value of pore size distribution in activated carbon materials as follows:

DatasheetDatasheet

Microporous analysis Report of carbon materials as below:

DatasheetDatasheet

Scientific Solutions

Scientific Solutions have been providing carefully selected laboratory and analytical equipment to Australian Industries such as Environmental, Pharmaceutical, Food and Beverage and Research markets of the Science Industry for over a decade.