CALL US

02 9543 7377

Power Prep/NG – Dioxins and PCBs Sample Prep System

An Overview of Multi-Column Sample Cleanup

Sample cleanup is a very important step because methods often don’t respond to the analyte in its in-situ form, or the results can be distorted by interfering species. Column cleanup is used to eliminate interferences that can occur in the sample matrices. Multi-column cleanup procedures use multiple column chemistries to remove interferences and fractionate analytes of interest from complicated sample matrices.

PowerPrep Multi-Column Sample Cleanup System

The PowerPrep™ Multi-Column Sample Cleanup System is the only automated sample processing system of its kind available today. It is an automated liquid chromatography system that performs simultaneous sample processing unattended. The total sample preparation process –­ sample loading, washing, elution, fraction collection and concentration — ­is performed automatically. The PowerPrep Multi-Column Sample Cleanup System is designed specifically to replace the difficult, error prone, labor intensive manual processes involved in sample cleanup for trace analysis. For the trace analysis of Persistent Organic Pollutants in all sample matrices, the PowerPrep Multi-Column Sample Cleanup System performs sample cleanup in a matter of hours, not days. Its modular design allows easy maintenance and expansion. The Sample Processing Module is designed for Multi-column sample cleanup and fractionation and the patented pump ensures precise solvent delivery to achieve reproducible results. The Multi-Column Sample Processing Module can be easily swapped out to perform single column sample cleanup chemistries which allows your lab to use the PowerPrep System for automating other sample prep processes. Samples are cleaned up and directly fractionated to the SuperVap Concentrator for unattended transfer and concentration directly to a vial. The SuperVap Concentrator is a dry, waterless, programmable system that can preheat as well as ramp up to final temperature. When the concentrator senses that the extracts are being delivered to each vessel it automatically starts the nitrogen blow down. It then shuts off the nitrogen blow down when each extract has achieved final volume.

Product Category: Dioxin and PCB Cleanup, Extraction/Concentration

Industry: Analytical and Environmental Labs, Food, Dairy and Wine

Supplier: FMS

Description

Automated Sample Cleanup for Trace Analysis
The Powerprep Multi-Column Sample Cleanup system automates error prone, tedious, manual sample cleanup and fractionation steps in the laboratory. It replaces older manual techniques by automating the sample loading, washing, elution, fractionation and evaporation steps of the process. It increases laboratory throughput by performing sample cleanup and fractionation in hours instead of days.

Rapid Sample Processing
The Power-Prep system, that automates the entire manual sample cleanup process, processes samples in hours versus days.

Cost Effective and Reliable Analysis
The system performs the entire column chromatography, automatically and unattended, and delivers consistent, reproducible recoveries for all analytes. Unattended operation of the system saves labor and time, reducing glassware and solvents. It automates difficult manual sample cleanup procedures specifically for the trace analysis of Dioxins, BFRs, PCBs, Pesticides and PAHs.

High Recovery of all Analytes
FMS columns are certified and guaranteed for the cleanup of samples for the trace analysis of Dioxins, PAHs, PBDEs, and PCBs producing the highest recoveries for all analytes of interest.

Modular, Expandable, and Affordable
The PowerPrep system is modular and can be expanded from 1 to 6 samples. Both expansion and module replacement are done via FMS’s quick connect modules reducing system down time, increasing laboratory throughput and eliminating cross contamination from sample to sample.

Disposable Columns
The PowerPrep System uses proprietary FMS columns made from teflon and contain packings such as multi-silica, acidic silica, basic silica, neutral silica, alumina, carbon and florisil. FMS columns are tested for purity and performance. Prior to shipment they are certified and guaranteed.

Easy Documentation
Programs and stores an unlimited number of methods and runs.

Specifications

Dimensions: 15” W x 18” D x 35” H

Weight: 130 lbs.

Pump: Piston Displacement

Flow rate: 0.2 to 15 mL/minute

Electrical Input: 110/220 Volts, 50/60 HZ

Controller: PC based

SuperVap Concentration System

Dimensions:13” W x 13” D x 12” H

Weight:20 lbs.

Gas Requirements: Nitrogen – 20 PSI minimum

Electrical Input: 110/220 Volts, 50/60 HZ

Controller: PC based

Bath: Dry

Whitepapers

Cooking up a Solution – Same Day Testing of Dioxins and PCBs for Food Safety is Now Feasible

The Analysis of Chlorinated Dioxins, Difurans and Polychlorinated Biphenyls in Edible Oils

Use of Pressurized Liquid Extraction and Automated Column Chromatography in the Analysis of Polychlorinated Dibenzo-p-dioxins, Furans and Biphenyls in Human Serum

Method for the Validation of PAHs in Soil and Sediment Samples Using Pressurized Liquid Extraction and Automated Cleanup

The Analysis of Polychlorinated Dibenzo-p-dioxins and Furans in Cranberry Pulp with Automated Extraction and Reduced Solvent Volume Clean Up

Fast Analysis of PCDD-F and DL-PCBs in Food Samples by Automated Pressurized Liquid Extraction and Cleanup

One Step Extraction and Cleanup System for Rapid Analysis of Dioxins, PCBs, PAHs and Other POPs in Food and Environmental Sample

The Analysis of Chlorinated Dioxins, Difurans and Polychlorinated Biphenyls in Edible Oils

The Analysis of Chlorinated Dioxins, Difurans in Pet Food

The Analysis of Polychlorinated Biphenyls in Coffee using Automated Extraction and Reduced Solvent Volume Clean Up

Automated Extraction and Cleanup of Egg Yolk Dioxins and Furans

Analyzing Infant Formula for Dioxins and Furans using Pressurized Liquid Extraction and Automated Cleanup

Automated Extraction and Clean Up of Crab Meat Dioxins and Furans

Dioxins, Furans, and PCBs in Peanut Butter Samples Processed with Automated Extraction and Clean Up

Analyzing Freeze-Dried and Regular Milk for Dioxins and Furans using Pressurized Liquid Extraction and Automated Clean Up

Polychlorinated Dibenzo-p-dioxins, Furans and Biphenyls in Fish Automated Sample Processing

Analysis of Chlorinated, Dioxins, Difurans and Biphenyls in Edible Oils Using Low Cost, Green, Automated Sample Cleanup

Scientific Solutions

Scientific Solutions have been providing carefully selected laboratory and analytical equipment to Australian Industries such as Environmental, Pharmaceutical, Food and Beverage and Research markets of the Science Industry for over a decade.

Please enter your name.
Please enter a message.