CALL US

02 9543 7377

Saccharimeter Autopol 880 PLUS & 880T PLUS

This is Rudolph’s latest and most advanced model. It was developed and tested in conjunction with labs testing pharmaceutical grade sugars. These labs require precise temperature control yet still want flow through cell type operation. For sugar trade labs and contract work that demands the best and most advanced saccharimeter in the world.

Product Category: Saccharimeters

Industry: Food, Dairy and Wine

Supplier: Rudolph Research Analytical

Description

Automatic Saccharimeters, Rudolph Research, AUTOPOL 880T & 880 PLUS Series

This is Rudolph’s latest and most advanced model. It was developed and tested in conjunction with labs testing pharmaceutical grade sugars. These labs require precise temperature control yet still want flow through cell type operation. For sugar trade labs and contract work that demands the best and most advanced saccharimeter in the world.
This option is only suitable for air conditioned modern laboratories.
The 880T saccharimeter is a dual wavelength microprocessor based saccharimeter capable of measuring at both 589 nm and 880 nm. The 880 nm ICUMSA Approved near infrared wavelength allows measurement of dark sugar factory juices, while the AUTOPOL Automatic Saccharimeter Purity Mode allows simultaneous measurement and display of PURITY, BRIX and POL.

Saccharimeter 880

Dual Wavelengths

The most important feature of the AUTOPOL® saccharimeter models IIZ, 88o, 880T, and 880 PLUS are their ability to measure at two wavelengths: 589 nm and 880 nm (NIR). Select 589 nm for conventional analysis using chemicals or lead clarifiers, or select 880 nm for polarimetric sugar measurements in the near infrared (NIR). 880 nm is above the absorption level of most dark sugar factory solutions allowing measurement of filtered but non-lead clarified juices. The dark sample measurement bar gets darker in proportion to the darkness of the sample being measured. When the bar is completely dark the instrument has reached its measurement limit. The 880T / 4W AUTOPOL® saccharimeter offers 2 additional wavelengths to further expand measurement options.

Patented TempTrol™ Technology Eliminates the Need for a Water Bath. Here is How the TempTrol™ System Works:

The 880T  saccharimeter offers Rudolph’s exclusive TempTrol™ System which allows push-button temperature control of your TempTrol™ 100mm cell, 200mm cell or Quartz Control Plate. Set the temperature, push “measure” and walk away. The AUTOPOL V will heat or cool to a predefined temperature and then provide you with the result, all in one easy step.
The TempTrol™ System will accurately control your sample temperature to within ±0.2°C. This is particularly important for laboratory work when measuring pharmaceutical grade sugars.

Dilution and Cell Length Correction

Whether your sugar analysis requires a 25mm, 50mm, 100 mm or 200 mm cell, whether you use 1/2 normal (13g/100ml), 1/4 normal (6.5g/100ml) or full weight sugar solutions, the AUTOPOL®  880 and 880T saccharimeters provide the correct multiplier to display the reading as if the sample were prepared as a 1 normal solution in a 200 mm optical path-length cell.

Automatic Calibration

Calibrating an AUTOPOL® saccharimeter is quick and simple. First, place a Rudolph Quartz Control Plate calibration standard on the optical rails and enter the Quartz Plate value in the appropriate window. Second, enter the temperature to correct the measurement to either the ICUMSA standard temperature of 20°C or the Tropical reference temperature of 27.5°C. Third, press 2 buttons and calibration is complete. (See Technical Bulletin 913 for more details on Rudolph Calibration Standards)
20yearbanner

All Rudolph Instruments carry our exclusive 20 Commitment to service your instrument.

Rudolph Research Analytical offers a comprehensive range of Preventive Maintenance and Service Programs. Rudolph has demonstrated a commitment to its customers by keeping installed instruments operational, not only for 20 years, but in some cases for over 40 years. This long-term commitment to keeping our instruments running makes the cost of ownership, over the life of a Rudolph Instrument, one of the lowest in the laboratory market segment. At the date this document was published, there is no other laboratory instrument manufacturer guaranteeing service and technical support for 20 years. View the entire 20 Service Guarantee. 

Specifications

AUTOPOL 880T & 880 PLUS SACCHARIMETER SPECIFICATIONS
Optical Wavelengths Standard - 589nm, 880nm Optional - 587nm, 882 nm
Wavelength Selection Selectable: 2 standard, 4 optional
Measuring Mode °Z (°ISS), Optical Rotation or User Defined Scale
Measuring Range ±89.9° Arc Optical Rotation, ± 259°Z (ISS)
Resolution 0.001° Arc Optical Rotation, 0.01°Z (ISS)
Reproducibility 0.001° Arc Optical Rotation, 0.01°Z (ISS)
Accuracy 0.01°Z (ISS)
Measuring Scale °Z (ISS)
Prism Glan Thompson Calcite
Temperature Control Standard - by external Water Bath Optional 880T - TempTrol electronic heating and cooling 18°C - 35°C
Temperature Correction 18°C - 40°C
TempTrol™ Accuracy Temperature accuracy determined by external Water Bath
Temp. Probe Range 10° - 40°C
Temp. Probe Accuracy ±0.1°C
Measurement Time 12°/sec
Light Source Tungsten-halogen 6V, 20W, Avg. 2,000 hr. life
Optional Light Source LED 20-30 mA 100,000 hr. avg
Sample Chamber Accepts sample tubes up to 200mm
Data Storage 32 GB SSD
Communication Interface 1 x Serial, 1 x VGA, 1 x HDMI, 2 x Cat 5, 4 x USB ports
Calibration Automatic calibration via touchscreen
Purity Software Standard
Connection to Refractometer Standard
Display 800 x 600 pixel resolution with 400 nits of brightness
User Interface Touchscreen
Automatic Sensitivity Control Measures samples with transmittance as low as 0.01% (up to O.D. 4.0)
Input Power 100 - 240 Volts, 50/60Hz
Operating Dimensions 30” W x 17” H x 11” D 762 mm W x 431.8 mm H x 279.4 mm D
Shipping Dimensions 42"W x 24"H x 21"D 1066.8mm W x 267mm H x 432mm D
Operating Weight 85 lbs. (39 kg)
Shipping Weight 120 lbs. (54.5 kg)

Brochures

Saccharimeters

Scientific Solutions

Scientific Solutions have been providing carefully selected laboratory and analytical equipment to Australian Industries such as Environmental, Pharmaceutical, Food and Beverage and Research markets of the Science Industry for over a decade.

Please enter your name.
Please enter a message.