
SmartChem 200
Product Category: Discrete Analysers
Industry: Analytical and Environmental Labs, Food, Dairy and Wine
Supplier: Alliance Instruments
Description
Automation Without Compromise
- all methods are stored in memory
- as many as six (6) methods can be programmed in a single run
- method changeover is automatic with all the chemistry requirements in place to include sample volume‚ reagents(s) volume(s)‚ dwell time‚ and optical filter
- no hardware changes from test-to-test
- no wasted reagents
- no baseline stabilization
- no pump tubes
- no flowing streams
- no shutdown
- prepare working standards from a stock solution
- prepare spiked samples and calculate recoveries
- rerun over range samples
- offers 5 modes of detection: endpoint‚ fixed time‚ differential‚ bichromatic‚ and kinetic
- QC charting
Applications
Both SmartChem® systems have extensive application lists for environmental, feeds, fertilizer, soil/plant tissue, tobacco and wine.
Environmental | |
Acidity Alkalinity, EPA 310.2 Aluminum, SM (20th) 3500 Al-B Ammonia, *EPA 350.1 Boron Calcium COD, EPA 410.4 Chloride, EPA 325.2 Chlorine, EPA 330.5 Chromium, SW846 7196A Cyanide, EPA 335.2, 335.4 Fluoride, EPA 340.1, 340.3 Fluoride, EPA 340.1, 340.3 |
Iron, SM(20th) 3500Fe-B Magnesium Manganese, SM (20th) 3500 Mn-B Nitrate, *EPA 353.2 Nitrite, *EPA 353.3, 354.1 Ortho Phosphate, *EPA 365.1, 365.2 Phenol, EPA 420.4 Silicate, EPA 370.1 Sulfate, EPA 375.4 Total Kjeldahl Nitrogen, *EPA 351.2 Total Kjeldahl Phosphorus, *EPA 365.4 Total Phosphorus, EPA 365.2 Hardness, EPA 130.1 |
*EPA Approval Letters - view in PDF format. | |
Agricultural Chemistries for Feeds/Fertilizers | |
Ammonia or Protein Calcium Phosphate |
Total Nitrogen Total Phosphorous Urea |
Soil/Plant Tissue | |
Ammonia Boron Calcium Chloride Lysine |
Nitrite Phosphate Total Nitrogen Total Phosphorous Urea |
Tobacco | |
Ammonia Chloride Cyanide for Smoke Formaldehyde for Smoke Nitrate |
Phosphate Reducing Sugars Total Sugars Urea |
Specifications
Size Weight Sample Capacity Reagent Capacity Reaction Temperature Reaction Cuvettes Detector Filter Wheel Linear Range Resolution Lamp Sample Blanking Sampling Rate Reaction Volume Auto Dilution Automated Standard Prep Low Reagent Alarm Low Sample Alarm Stand by Mode Automated Spike Prep Ambient Temperature Relative Humidity Sample Consumption Reagent Consumption Power Requirements |
39.5L" x 25.5D" x 16.5H" 137 lbs. 126 sample cups with continuous loading 16 positions, 40 mL volumes Adjustable, 30-45° C 60 semi-disposable cuvettes, 1 cm pathlength Dual-beam photometer with 20 bit resolution 10 filters: dark, 460, 480, 510, 520, 550, 570, 630, 660, 880 0.0001 to 2.500 AUFS 0.0001 AUFS 6V/10W halogen lamp User selectable Up to 180 tests per hour 290-600 uL Up to 100 x Yes Yes Yes Yes Yes 18-30° C 20-85% non-condensing 3 - 300 uL 3 - 300 uL 90-250 VAC 47-63 Hz 300 W |