CALL US

02 9543 7377

TurboTrace Sequential Parallel SPE

The TurboTrace Sequential Parallel Automated Solid Phase Extraction System is a One-Step Extraction and Concentration System is designed to streamline your laboratory’s workflow and increase productivity by automating the manual steps in your sample preparation process. The TurboTrace Sequential Parallel Automated Solid Phase Extraction System automates existing manual SPE techniques and replaces older manual Liquid-Liquid Extraction techniques and outdated semi-automated instruments.

Product Category: SPE Systems

Industry: Analytical and Environmental Labs, Food, Dairy and Wine

Supplier: FMS

Description

The TurboTrace Sequential Parallel Automated Solid Phase Extraction System is a One-Step Extraction and Concentration System is designed to streamline your laboratory’s workflow and increase productivity by automating the manual steps in your sample preparation process. The TurboTrace Sequential Parallel Automated Solid Phase Extraction System automates existing manual SPE techniques and replaces older manual Liquid-Liquid Extraction techniques and outdated semi-automated instruments.

The TurboTrace Sequential Parallel Automated Solid Phase Extraction System is the only SPE system that combines extraction, drying and concentration into one step — providing a truly automated total sample prep solution for the laboratory. Simply load samples onto the PowerPrep SPE system to trigger the automated extraction process. After loading the sample onto the SPE cartridge, the drying step is accomplished using Nitrogen. This drying step replaces manual techniques. The analytes of interest are then eluted directly to the SuperVap Concentrator where the concentration process automatically brings the extract to final volume and places it directly into an autosampler vial, ready for final analysis. Automating these processes into one step ensures the highest quality results in the shortest amount of time and eliminates both human error and the possibility of contamination.

The TurboTrace Sequential Parallel Automated Solid Phase Extraction System uses positive pressure pumping for precise and accurate delivery of conditioning, washing and elution solvents. The TurboTrace Sequential Parallel Automated Solid Phase Extraction System is specifically designed to isolate analytes of interest from a wide variety of liquid matrices such as urine, blood, water, milk, beverages. Sample sizes range from 2 mL to 8 L and use the same bottle the sample was collected in. Sample loading rates are programmable. A vacuum or positive pressure pump is used to load samples onto the SPE cartridges and columns at unprecedented speeds and it easily handles both clean and tough sample matrices. The TurboTrace Sequential Parallel Automated Solid Phase Extraction System concentrates samples up to 250 mL directly to a GC vial. The Sample Processing Module is designed to use all standard formats of SPE cartridges and columns on the market today. For guaranteed results, especially when dealing with low limits of detection, we recommend FMS prepacked columns and cartridges. Sample Processing Modules can be easily swapped out to perform cleanup column chemistries allowing the lab to multipurpose the PowerPrep to automate other sample prep processes.

Reduces Errors
One-step automated SPE and concentration eliminates human error, saves labor costs and reduces solvent usage while increasing your sample throughput

Fully Automated
Hyphenates the entire sample prep process–extraction, drying and concentration steps–into a one step program.

Runs up to five different methods/sample matrices sequentially

Concentrates samples up to 250 mL directly to a GC vial.

Automatic Sample bottle rinse

High Speed
The fastest automated sample processing available for SPE cartridges and columns

Run up to six samples simultaneously, up to 30 samples total

Vacuum for fast loading of large volume samples

Versatile
Handles a wide range of sample sizes and all matrix types

Sample Sizes 2 mL to 8 L

Expandable from 1 to 6 modules

Efficient
Uses all SPE cartridge and column sizes

Positive pressure pumping for loading small volume samples

Nitrogen drying

Compliant
Complies with existing methods that require vacuum, positive pressure pumping for the precise delivery of sample and solvents

Dispenses up to six solvents using an HPLC pump to deliver precise volumes and flow rates for conditioning and elution

Easy Documentation
Programs and stores an unlimited number of methods and runs

Easy-to-use software

Specifications

TurboTrace Sequential Parallel SPE

Dimensions: 15” W x 18” D x 35” H

Weight: 130 lbs.

Gas Requirements: Nitrogen – 20 PSI minimum

Vacuum Requirements: 25” Hg minimum

Pump: Piston Displacement

Flow rate: 0.2 to 15 mL/minute

Electrical Input: 110/220 Volts, 50/60 HZ

Controller: PC based

 

SuperVapVap Concentration System

Dimensions:7” W x 13” D x 12” H

Weight: 20 lbs.

Gas Requirements: Nitrogen – 20 PSI minimum

Electrical Input: 110/220 Volts, 50/60 HZ

Controller: PC based

Bath: Dry

Scientific Solutions

Scientific Solutions have been providing carefully selected laboratory and analytical equipment to Australian Industries such as Environmental, Pharmaceutical, Food and Beverage and Research markets of the Science Industry for over a decade.

Please enter your name.