EconoPrep Sample Cleanup for Dioxin and PCB Analysis
Product Category: Dioxin and PCB Cleanup, Extraction/Concentration
Industry: Analytical and Environmental Labs, Biodiesel/Petrochemical
Supplier: FMS
Description
Simultaneously perform eight Sample Cleanups and Concentrations in less than 1 hour
The EconoPrep systems are integrated, economical sample preparation systems that combine the sample cleanup, and evaporation steps into one automated process.
Unattended Sample Preparation
Install the cleanup columns on the system, push the “Run” button and walk away. The EconoPrep systems will automatically load a sample and perform the entire sample preparation process unattended, in virtually one step. The final fraction is ready for analysis by GC, LC, or GC/LC/MS.
Same Day Turn Around for Multiple Samples
Because the EconoPrep can process eight samples in parallel sample cleanup, and concentration. EconoPrep systems are able to turn around up to 64 samples in a day.
Greener Approach Dramatically Reducing Solvent Consumption
The greater efficiency with which the EconoPrep systems perform cleanup reduces solvent consumption.
-Solvent Consumption as low as 120ml
Dramatic Savings in Time and Resources
EconoPrep systems perform the complete preparation of eight samples in just a 30 minutes, instead of days. This results in time and labor savings as well as high throughput.
Low Background Automated Sample Prep
The advanced, closed loop system design combined with pre-packed, disposable columns deliver cleaner backgrounds and eliminate cross contamination.
Wide range of pre-packed, disposable cleanup columns
A wide variety of economical, pre-packed, disposable cleanup columns are available for use with EconoPrep systems. These columns are configured in a variety of sizes and packing material types − from standard multi-layered ABN silica to custom made columns.
Disposable Columns used for Dioxins and
PCBs, analysis:
1. Multi-layered ABN silica
2. Alumina
3. Carbon
4. High capacity acid silica (optional used for fatty samples, these column remove 5 to 7 grams of fat
Robust and Maintainable
The modular, flexible design of EconoPrep systems virtually eliminates downtime and makes them the most easily to maintain systems in today’s laboratories. Each system channel operates independently of the other channels, so if one channel malfunctions the others still work. Should a module malfunction, laboratory personnel can replace it on-site and the exposed construction makes parts accessible for easy replacement.
Specifications
Weights:
Control module = 22lbs
EconoPrep valve module = 31lbs
Control Module Base = 6 lbs
Single Base = 3 lbs
EconoPrep2 = 62lbs
EconoPrep4 = 97lbs
EconoPrep6 = 132lbs
EconoPrep8 = 167lbs
Small cart = 35lbs
Small tray = 20lbs
Medium cart = 40lbs
Medium tray = 25lbs
Large cart = 45lbs
Large tray = 35lbs
Dimensions:
EconoPrep2 = 16”(41cm)W X 26”(65cm) H X 17”(43cm) D
EconoPrep4 = 25”(63cm)W X 26”(65cm) H X 17”(43cm) D
EconoPrep6 = 34”(86cm)W X 26”(65cm) H X 17”(43cm) D
EconoPrep2 = 43”(110cm)W X 26”(65cm) H X 17”(43cm) D
Pump:
Piston Displacement Flow
Flow rate: 0.2 to 15ml/minute
Electrical Input:
110/220Volts, 50/60HZ
Controller:
Integrated Touch Screen Control
Whitepapers
Polychlorinated Dibenzo-p-dioxins, Furans and Biphenyls in Fish Automated Sample Processing
Automated Extraction and Cleanup of Egg Yolk Dioxins and Furans
Automated Extraction and Clean Up of Crab Meat Dioxins and Furans
Dioxins, Furans, and PCBs in Peanut Butter Samples Processed with Automated Extraction and Clean Up
One Step Extraction, Cleanup and Concentration for PBDEs in Soil
Automated Extraction and Clean Up of Wood Boiler Ash Samples Dioxins, Furans, and PCBs