Foam Tester

The SITA FoamTester analyses the characteristics of foam testing surfactant-containing liquids easy, fast and precise with automated foam testing measuring sequences.   • Fully automated Sita foam tester analysis • Precise reproducible foam formation • Innovative optical foam tester method • Sita Foam Tester Measures foam and liquid volume • Sita Foam tester Analyses foam structure • Recording drainage • Automated cleaning

Product Category: Foam Testing

Industry: Biodiesel/Petrochemical, Food, Dairy and Wine, Mining and materials, Particle and surface science, Pharmaceutical, Personal Care and Natural Products

Supplier: Sita

Description

Easy and Repeatable Testing and Monitoring of the Foaming Characteristics of Foaming Liquids
Functionial components of the SITA FoamTester
Benefits of automated foam testing
• Autonomous repetition of test runs without intervention by the user
• Immediate statements about the reproducibility
• Fast and easy screening of test and sample parameters
Convenient sample handling
• Automatic sample preconditioning (e.g. temperature, concentration of additives) with external devices
• Integrated sample reservoir with magnetic stirrer for running multiple test series
• Automated self-cleaning system with external liquid supply (e.g. tap water)
Flexible experimenting
• Easy and free creation of experiments at the office PC by drag‘n‘drop using fully parameterisable device tasks and supportive functions (loops and timers)
• Creating multiple re-usable templates and exactly repeatable test routines to select and start by a single touch at the device
• Instant start with test routines for typical applications pre-defined by SITA

 

Create foam

Differentiation of various sample formulations and reproducible test sequences using an application-oriented foam creation with proven SITA method
• Established SITA standardised stirring disc
• Variable stirring parameter: speed, duration, acceleration, direction, intervals
• Minor influence of the vessel glass on foam formation
• Removable measuring vessel with stirring unit

 

 

 

Measure foam

Use of optical, contactless measuring methods
• Foam Surface Scanner

Determination of the topography of the foam surface and therefore the total volume using the structured-light method

• Foam Interface Scanner

Determination of the foam structure and the liquid level by optimal use of a movable camera system, which illuminates and observes the measuring vessel at an angle Θ above the critical angle for total internal reflection

• Automatic acquisition of the total volume (liquid and foam) by the Foam Surface Scanner, of the residual liquid volume by the Foam Interface Scanner and of the foam volume in combination
• Analysis of the foam volume of clear and cloudy liquids
• Recording of the foam structure over the range of 130 mm x 50 mm
• All measurements in the same measuring vessel, connected to the thermal circuit

 

Analyse foam and understand foaming

• Convenient evaluation of measuring data with the software SITA-FoamLab in the office
• Complete transparency of the measuring progress and the results by intuitive visualisation
• Analysis of the slope and the resulting volume during foam formation
• Analysis of the foam decay and the drainage
• Analysis of bubble sizes and shapes in the foam structure
Differentiation of various sample formulations and reproducible test sequences using an application-oriented foam creation with proven SITA method
• Established SITA standardised stirring disc
• Variable stirring parameter: speed, duration, acceleration, direction, intervals
• Minor influence of the vessel glass on foam formation
• Removable measuring vessel with stirring unit

 

 

Use of optical, contactless measuring methods
• Foam Surface Scanner

Determination of the topography of the foam surface and therefore the total volume using the structured-light method

• Foam Interface Scanner

Determination of the foam structure and the liquid level by optimal use of a movable camera system, which illuminates and observes the measuring vessel at an angle Θ above the critical angle for total internal reflection

• Automatic acquisition of the total volume (liquid and foam) by the Foam Surface Scanner, of the residual liquid volume by the Foam Interface Scanner and of the foam volume in combination
• Analysis of the foam volume of clear and cloudy liquids
• Recording of the foam structure over the range of 130 mm x 50 mm
• All measurements in the same measuring vessel, connected to the thermal circuit
• Convenient evaluation of measuring data with the software SITA-FoamLab in the office
• Complete transparency of the measuring progress and the results by intuitive visualisation
• Analysis of the slope and the resulting volume during foam formation
• Analysis of the foam decay and the drainage
• Analysis of bubble sizes and shapes in the foam structure
• Comprehensive characterising of foam and foaming
- By the determination of further parameters such as half-life period and foam density
- By the individual height-dependent evaluation of foam structure parameters such as average bubble size or circularity index
- By tracking time dependent changes in the foam structure
- Flexible comparison by clear display of different measuring sequences
- Easy export of data and results for documentation

Specifications

Foam creation
Recommended sample volume (200 ... 500) ml
Usable measuring vessel volume 1,500 ml (incl. foam)

Dimensions:
height 180 mm
diameter 110 mm

Capacity of sample reservoir 2,000 ml
Sample tempering of measuring vessel and sample reservoir (0 ... 60) °C using a optional thermostat
Stirring speed (0 ... 2,000) U/min (bidirectional)
Adjustable stirring programs speed, duration, direction, acceleration
Analysis of foam volume (foam creation and decay)
Measurement values total volume, foam volume, liquid volume
Evaluated parameters max. foam volume, foam half-life, flash foam
Measuring range total volume (0 ... 1,500) ml; resolution 1 ml
Measuring range liquid volume (0 ... 500) ml; resolution 1 ml
Analysis of foam structure
Parameters number of bubbles, bubble size distribution, average bubble diameter, circularity index
Evaluation area height 130 mm
width 50 mm
Resolution 3,200 dpi
General data
Rinse connection 3/4“ (2 ... 6) bar
Operating temperature (10 ... 40) °C
Power supply (100 ... 240) V / (50 ... 60) Hz,
300 W
Dimensions (HxWxD) (770 x 450 x 305) mm
Weight approx. 35 kg
PC interface Ethernet

Videos

Model comparison

SITA Foam Testing System Expert

consisting of SITA FoamTester und SITA-FoamLab Expert

SITA Foam Testing System Basic

consisting of SITA FoamTester und SITA-FoamLab Basic

Convenient sample handling • •
Flexible experimenting • •
Application-oriented foam generation with proven SITA method • •
Optical, contact-free measuring systems • •
Foam creation analysis • •
Foam decay analysis • •
Foam structure analysis • •

Scientific Solutions

Scientific Solutions have been providing carefully selected laboratory and analytical equipment to Australian Industries such as Environmental, Pharmaceutical, Food and Beverage and Research markets of the Science Industry for over a decade.

Please enter your name.