CALL US

02 9543 7377

PLE for Ethanol Extraction

Efficient, Fast, Safe Ethanol Extraction of Cannabis Oil

Integrated Ethanol Extraction, Cleanup and Oil Concentration Ready for Production A single module PLE sending oil from 2 ounces of flower extracted directly to a SuperVap® Concentrator is  capable of processing 4 lbs in 8 hrs. The PLE can be expanded up to 8 modules for extracting up to 8 modules in parallel, capable of processing 32 lbs. in 8 hrs. • One Extraction Method for all Solvents • High Speed, Extract in Minutes Not Hours • Modular, Expandable and Scalable from 1 to 8 Extractors • Process 2 oz. to 1 lb. in 10 min • Extraction Cell Sizes 5 to 200 ml • Real Time Plot of Temperature and Pressure • Dramatically Reduces Solvent • Works Efficiently • Environmentally Safe Process • Lower Energy Consumption • Supercooled Solvent for Cleanup • Optional Automated Evaporation • Easy to Use Touch Screen

Product Category: Extraction/Concentration

Industry: Cannabis

Supplier: FMS

Description

The PLE system is a high-speed pressurized liquid extraction system designed to perform  extraction of multiple compounds in the extraction of oil from cannabis simultaneously. The PLE system delivers high recoveries and yields with excellent precision of all cannabinoids in minutes instead of hours. Inexpensive stainless steel extraction cells with end cap filtration keep operational costs at a minimum. Reusable end cap filtration increases productivity and saves valuable time. Combining supercooling for cleanup eliminates extra manual cleanup steps required by other  techniques increasing throughput while reducing  human  interaction.

HIGH SPEED EXTRACTIONS

  • Most Efficient > 90%
  • Highest Yield up to 30%
  • 10 Minute Extraction
  • Supercooled Cleanup
  • From 4 Lbs. to 32 Lbs. in 8 Hrs.

Modular, Expandable and Affordable from 1 to 8 modules
The modular design of the PLE system allows you to purchase a one, two up to eight sample system to fit your budget. The system can be expanded from a one to eight sample system as your work load grows.

Reduce Solvent Waste
The PLE system reduces solvent waste by using solvents more efficiently. Cut solvent consumption in half.

Increase Productivity
The entire extraction and cleanup is performed in minutes. Traditional methods can take hours.

Reduce Operating Costs
Rapid extraction and clean-up, along with reduced solvent use and waste, reduces operating costs by as much as 70 percent.

5 to 200 mL Extraction Cell Sizes
The PLE system offers 5-200 mL low cost stainless steel extraction cells with Teflon endcap filtration. This wide range of extraction cell volumes allows the use of the same unit for all sample sizes, even in the same run.

Eliminate cross contamination
Low-cost stainless steel extraction cells and Teflon filtration endcaps ensure trouble-free extraction and eliminate the risk of cross contamination.

Sample Extraction and Cleanup in one step
The PLE uses incell cleanup and performs the entire sample extraction and cleanup in one step with increased speed and reduced cost. Eliminating additional manual cleanup steps. Just inject the sample extract.

Automatic Operation and Documentation
Real-time software allows eight channels of pressure and eight channels of temperature data to be plotted simultaneously. Allows automatic documentation of all extraction data.

One Extraction Method for All Matrices
A single extraction method is used for all cannabinoids and terpenes. A single extraction and cleanup method is used for extractions for all sample types. Eliminating the need to develop and validate several extraction protocols.

Scientific Solutions

Scientific Solutions have been providing carefully selected laboratory and analytical equipment to Australian Industries such as Environmental, Pharmaceutical, Food and Beverage and Research markets of the Science Industry for over a decade.

Please enter your name.